Mispa i2

Mispa i2

Specific Protein Analyzer

Overview

Mispa-i2 is a semi-automated specific protein analyzer that offers high precision and quick turnaround results, for all protein assays in blood testing and supports the clinical management of variety of diseases such as Diabetes, Cardiovascular risk, Inflammation, etc. Mispa i2 has a patented Unique Channel Shifting (UCS) technology for best sensitivity and high linearity which ensures quality results.

Specific Protein Analyzer – Mispa i2

What is protein analysis and how can it be done with a protein analyzer?

Proteins are large, complex molecules that play many critical roles in the body. Proteins differ from each other in their size, molecular structure, and physiochemical properties. These differences allow for protein analysis, and it is the standard method of protein analysis to determine protein concentration.

The large-scale study of proteins is called Proteomics. Protein quantification is necessary to understand the protein content in a sample and further prognosis. A protein analyzer is a handy laboratory tool for determining the protein quantity in a sample. 

Characteristics of an ideal protein analyzer

  • Wide assay panel & compatibility for various special assays
  • Single and Multilevel calibration
  • Simple testing procedure and fast reporting
  • Wide measuring ranges with high linearity & sensitivity
  • Prozone detection feature to avoid false reporting
  • STAT facility to run urgent samples
  • User-friendly interface
  • Result accuracy & precision

Physical characteristics of Mispa-i2 specific protein analyzer

Characteristic

Details

Dimensions

210x360x150 (LxWxH in mm)

Weight

2.8Kg

Keyboard

Numeric and Functional Keys (21 Keys)

Display

128 x 64 Graphical Display

Printer

Inbuilt Thermal Graphical printer

Barcode Interface

Handheld (Optional)

Features of Mispa-i2

  • 25 Parameter Assay Panel – Serving different profiles

Mispa i2 serves 25 parameters with better sensitivity and linearity which ensures flexibility in laboratory testing with marginal investment. Mispa i2 offers reliable results with a convenient pack size for all 25 parameters. The assay panel includes cardiovascular risk profile, allergy profile, covid profile, diabetic profile, rheumatology profile, osteoporosis screen profile, etc. Major parameters include HbA1c, CRP, RF, ASO, D Dimer, Ferritin, Microalbumin, immunoglobulins, Cystatin C, C3, C4, etc.

  • Smart Card Calibration -Technology to reduce the manual errors          

Each reagent pack of Mispa i2 comes with a smart card which contains lot-specific calibration data. Mispa i2 offers automated smart card calibration. The smart card calibration feature omits the need for a lengthy calibration process and reduces manual calibration errors. It also saves calibration costs, and reagent costs, and saves time. Hence this feature is quite beneficial for parameters like HbA1c, CRP, RF, etc. which require multipoint calibration. 

  • Prozone Detection System – Reduces the chance of false reporting

The rate-based nephelometry technique used in Mispa i2 helps in prozone detection and thus reduces false reporting chances. Mispa i2 reads the rate of absorbance continuously, and any repetition of similar absorbance at two different time instants is equivalent to the excess of antigen or antibody in the reaction cuvette (prozone or Kendall effect).

  • Unique Channel Shifting Technology – UCS is an intelligent technology that automatically shifts between the two reading channels (nephelometry & turbidimetry) based on the rate of the reaction. This dual measuring technology and unique channel shifting technology of Mispa i2 ensure accurate and precise results over a wide measuring range.
  • 500 Result Memory with an effective result retrieval system for better user convenience.
  • Auto Rotation & Auto Mixer– The cuvette holder senses the reaction cuvettes and ensures automatic uniform mixing through auto rotation.
  • 30 min. battery backup offers uninterrupted testing provision during power failure
  • NGSP-approved HbA1c reagents ensure accurate HbA1c results
  • LIS Compatibility offers unparallel user convenience for data transfer
  • 3-step user-friendly operating procedure
  • Faster reporting – Results provided within 5 minutes for all parameters
  • Zero auxiliary reagents cost – Since there is no liquid flow system in Mispa i2, we do not require any washing or cleaning reagents for maintenance. Hence, zero maintenance cost.
  • Zero additional cost for cuvettes and microtips – Each reagent kit comes with an accessory box which includes the cuvettes, reagent tips, and sample tips.

Technical Specifications of Mispa-i2 specific protein analyzer

 

Characteristic

Details

Principle

Rate Based Nephelometry and Immuno Turbidimetry

Calibration

Smart Card

Light Source

Laser LED | 650nm

Photo Detectors

Laser Detector

Laser Power

5mW

Temperature Control

Dry Heating

Temperature Range

Controlled 37 degrees Celsius

Mixing

Automatic by motor

Zero Setting

Automatic

PC Interface

RS 232 Port

Power Supply

85-240 VAC 50/60/HZ

Power Consumption

100W

 

 

Free Accessories of Mispa-i2 specific protein analyzer

Accessory name

Quantity in Nos.

R1 Pipette 20 – 200 µL

1

Sensor Pipette 20 – 200 µL

1

Micro Pipette 2 – 20 µL

1

Cuvette Stand

1

Pipette Stand

1

Printer Rolls

2

Free Accessories with Mispa-i2 reagents

Accessory name

Quantity in Nos.

Smart Card

1

Reaction Cuvette

15/30/100

Micro Tips

45/90/300

Controls & Calibrators of Mispa-i2 specific protein analyzer

Item No.

Name

Pack size

Product Group

51612004

Lipid Control ( Bi level) 2 x 1 mL

2 x 1 mL

Controls & Calib

51625002

HbA1c Control Level 2 x 0.5 mL

2 x 0.5 mL

Controls & Calib

51635002

Microalbumin Control ( Bi level) 2 x 1 mL

2 x 1 mL

Controls & Calib

51614007

Protein Control ( Bi level) 2 x 1 mL

2 x 1 mL

Controls & Calib

51630003

D-Dimer Control ( Bi level) 2 x 0.5 mL

2 x 0.5 mL

Controls & Calib

Awards and recognitions received for Mispa-i2 specific protein analyzer

  • Mispa i2 has received patent in 2012for its Unique Channel Shifting (UCS) technology.
  • Mispa-i2, The Specific Protein Analyzer from Agappe is the recipient of the All-India Management Association (AIMA) innovation award in March 2014.
  • Asian Healthcare Leadership Award in September 2014,
  • Confederation of Indian Industries award for innovation in November 2014.
  • KMA- Corporate Excellence award Innovations in 2015
  • Mispa i2 is proudly invited by ICMR to showcase at the Exhibition on “Innovations in Medical Science and Biotechnology” at Rashtrapathi Bhavan on 11 Mar 2015.

Reviews

There are no reviews yet.

Be the first to review “Mispa i2”

Your email address will not be published. Required fields are marked *

Top